RK120-07 The wind speed and direction meter is a kind of measuring instrument which uses the time difference of ultrasonic wave in the air to measure the wind speed and direction. RK120-07 uses low-power chip with power consumption of only 0.2W, which is especially suitable for solar or battery powered environment with high power consumption requirements. Due to the adoption of new technology and new process, the structure is more compact and compact. Optional temperature and air pressure module.
FEATURES
* Adapt to complex weather conditions
* No moving parts, long service life
* The surface preservative treatment
* Strong anti-interference
* High accuracy
APPLICATIONS
* Environmental monitoring
* Sea-going vessel
* Bridge & Tunnel
* Solar and wind power generation
* Wind resource assessment
* Drilling platform
* Automatic weather station
* Agriculture
SYSTEM TECHNICAL SPECIFICATION
Item
|
Technical Specification
|
Power Supply
|
12-24VDC
|
Power consumption
|
1.7W
|
Output Signal
|
4-20mA①,RS232/RS485(Modbus or NMEA-183), SDI-12
|
Operating Temperature
|
-30℃-+60℃
|
Ingress Protection
|
IP65
|
Dimension
|
Ф82*108mm
|
Weight(unpacked)
|
0.8kg
|
Main material
|
ABS
|
Item
|
Technical Specification
|
Range
|
Resolution
|
Accuracy
|
Wind speed
|
0-40m/s
|
0.1m/s
|
±3%
|
Wind direction
|
0-360°
|
1°
|
±3°
|
Starting Threshold
|
0.1m/s
|
0.1m/s
|
|
Extreme Wind Speed
|
60m/s
|
①When there are only two parameters of wind speed and wind direction, 4-20mA output can be selected.
MOUNTING & DIMENSION
For indoor use, the sensor can be used at any where .Directional installation to measure wind speed on different planes.
Step1:
Positioning: generally, RK120-07 is installed in a vertical installation pipe .ensure the measurement on the same level.
Step2:
There is rotary adjustable mounting holes at the bottom of the senor,when mounting the sensor, to ensure the indicator on on the sensor comply with the geographic north.
Step3:
Installation: the installation pipe needs 3 equally spaced holes, tapping M5 screws, position7.5mm from the top of the pipe.

PARAMETER SELECTION TABLE
Remark
|
Series
|
Type
|
Parameter |
Supply
|
Output
|
Cable length
|
|
RK
|
|
|
|
|
|
|
|
|
120
|
|
|
|
|
|
|
|
|
07
|
|
|
|
|
|
|
|
|
A |
|
|
|
With atmospheric pressure |
|
|
|
|
A |
|
|
12-24V |
|
|
|
|
X |
|
|
Other |
|
|
|
|
|
A |
|
4-20mA |
|
|
|
|
|
B
|
|
|
|
|
|
|
|
C
|
|
RS485(Modbus)
|
|
|
|
|
|
D
|
|
RS485(NMEA-183)
|
|
|
|
|
|
E
|
|
RS232(Modbus)
|
|
|
|
|
|
F
|
|
RS232(NMEA-183)
|
|
|
|
|
|
G |
|
SDI-12 |
|
|
|
|
|
|
4000
|
4m,default
|
|
|
|
|
|
|
10000
|
10m
|
|
|
|
|
|
|
...
|
|
Example: RK120-07AAG4000 With atmospheric pressure, Supply:12-24V, Output: SDI-12 Cable length:4m.