Tel / Fax: +86-731-85132979 Email: info@rikasensor.com
Web Search: Goods

     

Your present location:HomeproductsSolar & Light Detector - RK200-02 PAR Sensor
  • Product Name: RK200-02 PAR Sensor

The RK200-02 PAR Sensor is mainly used for measuring solar radiation within 400~700nm wavelength. It is easy installation and can work continuously in all weathers. When there is sunlight, voltage output proportional to incident light intensity will be generated by the silicon-photo detector in the sensor. Its sensitivity is proportional to the cosine of incident light direct angle. Each product is with one sensitivity coefficient respectively. It can directly output radiation value in unit of μ*mol/m2*s.

FEATURES

  * Metal construction
  * Harsh environment workable
  * High sensitivity
  * No power supply measurement
  * Compact size for easy use

APPLICATIONS

  * Agrometeorological research
  * Crop growth monitoring
  * Ecological research
  * Environment surveillance
  * Greenhouse control

SPECIFICATIONS

Item

Specifications

Spectral range

400~700nm

Accuracy

±5% rdg

Range

0-2500μ*mol/m2*s or 0-2000W/m2

Supply

5VDC,12V-24VDC

Output

0-2000mV,4-20mA,0-5V,RS485

Sensitivity(0-2500μ*mol/m2*s)  160-1000μv/μ*mol*m2*s, 6.4μA/μ*mol*m 2 *s

Sensitivity(0-2000W/m2)

1000μV/W/m 2, 0.8uA/W/m 2

Response time

<1s(99%)

Temperature effect

<0.05%/℃

Cosine correction

<10%(until 80°)

Non-linearity

<±2%

Operating temperature

-40-+80℃

Shell material

Aluminum alloy

Storage Condition

10℃-60℃@20%-90%RH

OUTPUT CHARACTERISTICS

0-2000mV

Range:0-2000W/m 2 PAR values(W/m 2 )= Voltage output value(μV)/1000
Range:0-2500μ*mol/m 2 *s PAR values(μ*mol/m 2 *s)= Voltage output value(μV)/160

4-20mA

Range:0-2000W/m 2 PAR values(W/m2)=(I(μA)-4000μA)/0.8(Where I is output current value,unit:μA )
Range:0-2500μ*mol/m 2 *s PAR values(μ*mol/m 2 *s)= (I(μA)-4000μA)/6.4(Where I is output current value,unit:μA )

RS485
MODBUS-RTU

DIMENSION

Unit:mm

In order to ensure measurement accuracy, please keep the horizontal installation.


PARAMETER SELECTION TABLE

Remark

Series

Type

Supply

Range

Output

Cable Length

 

RK

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

02

 

 

 

 

 

      A       5V
      B       12-24V
      X       Other

 

 

 

 

A

 

 

0-2500μ*mol/m2*s

 

 

 

 

B

 

 

0-2000W/m2

 

 

 

 

C

 

 

Other

 

 

 

 

 

A

 

4-20mA

 

 

 

 

 

B

 

0-5V

 

 

 

 

 

C

 

 

 

 

 

 

 

D

 

0-2000mV

 

 

 

 

 

E

 

RS485(0-2000W/M2)

 

 

 

 

 

X

 

Other

 

 

 

 

 

 

1500

Units:mm(typ)

 

 

 

 

 

 

3000

Units:mm

 

 

 

 

 

 

...

Units:mm

Example: RK200-02BBA1500 Supply:12-24V,Range: 0-2000W/m2,Output:4-20mA,Cable Length:1.5m.

    