  • Product Name: RK600-03 Data Logger

RK600-03 General Color Data Logger contains the signal collection, display, processing, operation, alarm, recording and other functions, with 18 analog signal input channels, 4 relay alarm output, 150 mA power output capacity( 6 channels two wire transducer or 2 channels four wire transducer), 1 RS485 communication interface and 1 USB data transfer.
The product adopts high-speed, high-performance 32-bit CPU(M4 microprocessors), PCB after "anti-corrosion,moisture-proof & dust-proof" three prevention treatment.Have strong anti-interference ability.
The recorder can be used in metallurgical, meteorology, petroleum, chemical industry, building materials, paper, electricity, food, pharmaceutical and industrial water treatment and other industries.

FEATURES

  * TFT color LCD display
  * 18 analog channels input
  * Power-fail protection
  * Optional RS485(RTU) output
  * Support alarm and control function
  * With 8G U-disk external storage

SPECIFICATION

Item

Details

Display

3.5” TFT true color LCD display, 320 * 240 resolution, high-definition LED back-light, three side close to zero point of view

Input channels

1-18 optional(signal type can be configured)

Input signal

Current:4-20mA,0-10mA,0-20mA
Voltage:0-5V,0-10V,1-5V
Thermocouple:B,E,J,K,S,T,R,N
Thermal resistance:Cu50,PT100
Other signals can be customized

Accuracy

0.2%FS

Internal storage capacity

48M

External storage

U-disk(attached)

Supply

AC220V,DC24V

Power consumption

20VA(max.)

Operating temperature

-10-+55℃@10-85%RH

Storage condition

-20-+60℃@5-95%RH

Communication mode

RS485(MODBUS-RTU),RS232(add external module)

Output capability

3.6W(24V@150mA)

Sample Period

1s

Power-drop protection

Data stored in the internal flash, historical data and configuration parameters will not be lost when power supply drop

Alarm output

Max.4 channels relay NO,250V/2A

Dimension

96*96*100mm(hole size:92*92mm)

Installation of panel thickness

1.5-6mm

Weight(unpacked)

370g

Dimension

Unit:mm

MOUNTING

INPUT CONNECTION

CONFIGURATION INSTRUCTIONS

Input Settings


Configuration
Item

Function Description

Parameter range

Channel

Select set analog channel

AI1~AI18

Bit

Set bit of the analog channel

Custom string’s length is 8

Unit

Set the unit for analog channel

Custom string’s length is 8

Signal

Setting Signal Types

(4~20) mA,( 0~20) mA,( 0~10)mA, 
PT100, Cu50,(1~5)V,(0~10)V,(0~5) V, 
B, E, J, K, S, T,R, N

Lower Range limit

Set lower Range limit

-99999~99999

Upper Range limit

Set upper range limit

-99999~99999

Correction factor A

A in Y=A*X+B

-99999~99999

Correction factor B

B in Y=A*X+B

-99999~99999

First-order filter

First-order filter parameter

0s,1s,2s,5s,10s,15s

Disconnection display

Displays the value of channel disconnection

-99999~99999

Alarm setting

Enter to alarm setting screen.

 

Alarm setting

Configuration Item

Function Description

Parameter range

Higher alarm HH

Higher alarm value

-99999~99999

Higher alarm output

Higher alarm output terminal

None, DO1, DO2, DO3, DO4

High alarm Hi

High alarm value

-99999~99999

High alarm output

High alarm output terminal

None, DO1, DO2, DO3, DO4

Low alarm Lo

Low alarm value

-99999~99999

Low alarm output

Low alarm output terminal

None, DO1, DO2, DO3, DO4

Lower alarm LL

Lower alarm value

-99999~99999

Lower alarm output

Lower alarm output terminal

None, DO1, DO2, DO3, DO4

Return difference

Alarm return difference

-99999~99999

Note : Return difference prevents repeated alarm when the measures date fluctuates from the alarm point. Here is the example of high alarm and return difference.

Function setting
Communication Settings
Instrument Support host computer communication operation to achieve real-time monitoring.

Configuration Item

Function Description

Parameter range

Instrument address

Modbus Device Address

1~254

Baud Rate

Communication speed

1200,9600,57600,115200

Parity bit

Communication verify

No parity, odd parity, even parity

Floating-point format

Floating point format

1234,2143,3412,4321

U disk operation
The instrument support U disk as an external storage media, which will save the historical data or various kinds of information to computer through U disk to permanently saved.

configuration Item

Function Description

File format

Save historical record

 

 

Save all the data in the HDR

Save all the data in the HDR format

HDA(.HDA)

Save all the data in the CSV

Save all the data in the CSV format

Text (.csv)

Save all the data in the HDA

Save all the data in the HDA format

Text (.csv)

Save the cumulative report

Save all the cumulative report

Text (.csv)

Save the alarm information

Save all the alarm information

Text (.csv)

Save the power-fail record

Save all the power-fail record

Text (.csv)

Save the log record

Save all the log record

Text (.csv)

Save the Instrument configuration

Save the current instrument configuration

CFG(.cfg)

Read the instrument configuration

Read instrument configuration in U disk
Note: When configuring is scanned when U
disk is inserted. Newly saved configuration
will be displayed when re-plug the U disk.

 

Path to save
The file of the instrument saved the corresponding file of U root directory whose name is [Instrument name].
File name:

File

Subdirectory

File name

History record

/History

H161009A.csv/ H161009A.hda

Cumulative Report

/Info

A161009A.csv

Alarm information

/Info

B161009A.csv

Power-fail record

/Info

P161009A.csv

Log records

/Info

L161009A.csv

Note:
Initial letters H, A, B, P, L represent types of files.
The numbers represents the date on which you save the file.
The last letter can be one of the letter from A to Z. it represents that you can save one type of file up to 23times a day.
Clear operation

Configuration Item

Function Description

Clear all the accumulated value

 

Clear all the accumulated reports

 

Clear the alarm information

Clear all the alarm information

Clear all the power-fail records

Clear all the power-fail records

Clear the log records

Clear all the log records

System Settings

Configuration item

Function Description

Parameter range

Supplier password

Set supplier password

000000~999999

Acquirer password

Set acquirer password

000000~999999

Instrument name

Set instrument name

Strings of 8 bytes

System time

Set system time

 

Time format

Set time format

YY-MM-DD, DD-MM-YY,
MM-DD-YY

Recording
interval

Set recording interval

1s,2s,5s,10s,15s,30s,1s,2s,
5s,10s,30s,60s

Startup screen

Set the default start up screen.

Front Panel ,digital display screen,
history screen

Cycle Time

The screen displays the cycle time of grouping

0s, 5s, 10s, 30s

Atmospheric pressure MPa

Set the Atmospheric pressure of the instruments

-999999~9999999

Restore factory configuration

Restore factory configuration

 

PARAMETER SELECTIONTABLE

Remark

Series

Type

Analog input

Alarm output

Communication

Power output

Supply

 

RK

 

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

 

 

03

 

 

 

 

 

 

 

 

 

01

 

 

 

 

1 input channel

 

 

 

02

 

 

 

 

2 input channels

 

 

 

...

 

 

 

 

...

 

 

 

18

 

 

 

 

18 input channels

 

 

 

 

A0

 

 

 

Without relay output

 

 

 

 

A1

 

 

 

With 1 relay output

 

 

 

 

A2

 

 

 

With 2 relay output

 

 

 

 

A3

 

 

 

With 3 relay output

 

 

 

 

A4

 

 

 

With 4 relay output

 

 

 

 

 

T0

 

 

Without Communication

 

 

 

 

 

T2

 

 

With RS232(add external module)

 

 

 

 

 

T4

 

 

With RS485

 

 

 

 

 

 

P0

 

Without power output

 

 

 

 

 

 

P1

 

With power output

 

 

 

 

 

 

 

A

AC220V

 

 

 

 

 

 

 

D

DC24V

    